top of page
WDRFA06_ACB1_24

WDRFA06_ACB1_24

SKU: WDRFA06_ACB1_24

Proportional spool valve (integrated electronics and LVDT)

 

Direct operated

 

Rated Size: NG6

 

More Information at Manufacturers Website: http://www.wandfluh.com/products/detail/wdrfa06-acb1-24/

 

Lead time is normally 2-3 weeks. Call for pricing and availability.

  • Product Options

    WDRFA06-ACB1 - R-10-24-A2_ 10 l/min ACB1-S only With analog command value signal (-10…+10 V preadjusted) Amplifier
    WDRFA06-ACB1 - R-10-24-A2R1 10 l/min ACB1-S only With analog command value signal (-10…+10 V preadjusted) Controller with current feedback value signal (0…20 mA / 4…20 mA)
    WDRFA06-ACB1 - R-10-24-A2R2 10 l/min ACB1-S only With analog command value signal (-10…+10 V preadjusted) Controller with voltage feedback value signal (0…10 V)
    WDRFA06-ACB1 - R-10-24-C1_ 10 l/min ACB1-S only With CANopen according to DSP-408 Amplifier
    WDRFA06-ACB1 - R-10-24-C1R1 10 l/min ACB1-S only With CANopen according to DSP-408 Controller with current feedback value signal (0…20 mA / 4…20 mA)
    WDRFA06-ACB1 - R-10-24-C1R2 10 l/min ACB1-S only With CANopen according to DSP-408 Controller with voltage feedback value signal (0…10 V)
    WDRFA06-ACB1 - R-10-24-P1_ 10 l/min ACB1-S only With CAN J1939 (on request) Amplifier
    WDRFA06-ACB1 - R-10-24-P1R1 10 l/min ACB1-S only With CAN J1939 (on request) Controller with current feedback value signal (0…20 mA / 4…20 mA)
    WDRFA06-ACB1 - R-10-24-P1R2 10 l/min ACB1-S only With CAN J1939 (on request) Controller with voltage feedback value signal (0…10 V)
    WDRFA06-ACB1 - R-20-24-A2_ 20 l/min ACB1-R only With analog command value signal (-10…+10 V preadjusted) Amplifier
    WDRFA06-ACB1 - R-20-24-A2R1 20 l/min ACB1-R only With analog command value signal (-10…+10 V preadjusted) Controller with current feedback value signal (0…20 mA / 4…20 mA)
    WDRFA06-ACB1 - R-20-24-A2R2 20 l/min ACB1-R only With analog command value signal (-10…+10 V preadjusted) Controller with voltage feedback value signal (0…10 V)
    WDRFA06-ACB1 - R-20-24-C1_ 20 l/min ACB1-R only With CANopen according to DSP-408 Amplifier
    WDRFA06-ACB1 - R-20-24-C1R1 20 l/min ACB1-R only With CANopen according to DSP-408 Controller with current feedback value signal (0…20 mA / 4…20 mA)
    WDRFA06-ACB1 - R-20-24-C1R2 20 l/min ACB1-R only With CANopen according to DSP-408 Controller with voltage feedback value signal (0…10 V)
    WDRFA06-ACB1 - R-20-24-P1_ 20 l/min ACB1-R only With CAN J1939 (on request) Amplifier
    WDRFA06-ACB1 - R-20-24-P1R1 20 l/min ACB1-R only With CAN J1939 (on request) Controller with current feedback value signal (0…20 mA / 4…20 mA)
    WDRFA06-ACB1 - R-20-24-P1R2 20 l/min ACB1-R only With CAN J1939 (on request) Controller with voltage feedback value signal (0…10 V)
    WDRFA06-ACB1 - S-10-24-A2_ 10 l/min ACB1-S only With analog command value signal (-10…+10 V preadjusted) Amplifier
    WDRFA06-ACB1 - S-10-24-A2R1 10 l/min ACB1-S only With analog command value signal (-10…+10 V preadjusted) Controller with current feedback value signal (0…20 mA / 4…20 mA)
    WDRFA06-ACB1 - S-10-24-A2R2 10 l/min ACB1-S only With analog command value signal (-10…+10 V preadjusted) Controller with voltage feedback value signal (0…10 V)
    WDRFA06-ACB1 - S-10-24-C1_ 10 l/min ACB1-S only With CANopen according to DSP-408 Amplifier
    WDRFA06-ACB1 - S-10-24-C1R1 10 l/min ACB1-S only With CANopen according to DSP-408 Controller with current feedback value signal (0…20 mA / 4…20 mA)
    WDRFA06-ACB1 - S-10-24-C1R2 10 l/min ACB1-S only With CANopen according to DSP-408 Controller with voltage feedback value signal (0…10 V)
    WDRFA06-ACB1 - S-10-24-P1_ 10 l/min ACB1-S only With CAN J1939 (on request) Amplifier
    WDRFA06-ACB1 - S-10-24-P1R1 10 l/min ACB1-S only With CAN J1939 (on request) Controller with current feedback value signal (0…20 mA / 4…20 mA)
    WDRFA06-ACB1 - S-10-24-P1R2 10 l/min ACB1-S only With CAN J1939 (on request) Controller with voltage feedback value signal (0…10 V)
    WDRFA06-ACB1 - S-20-24-A2_ 20 l/min ACB1-R only With analog command value signal (-10…+10 V preadjusted) Amplifier
    WDRFA06-ACB1 - S-20-24-A2R1 20 l/min ACB1-R only With analog command value signal (-10…+10 V preadjusted) Controller with current feedback value signal (0…20 mA / 4…20 mA)
    WDRFA06-ACB1 - S-20-24-A2R2 20 l/min ACB1-R only With analog command value signal (-10…+10 V preadjusted) Controller with voltage feedback value signal (0…10 V)
    WDRFA06-ACB1 - S-20-24-C1_ 20 l/min ACB1-R only With CANopen according to DSP-408 Amplifier
    WDRFA06-ACB1 - S-20-24-C1R1 20 l/min ACB1-R only With CANopen according to DSP-408 Controller with current feedback value signal (0…20 mA / 4…20 mA)
    WDRFA06-ACB1 - S-20-24-C1R2 20 l/min ACB1-R only With CANopen according to DSP-408 Controller with voltage feedback value signal (0…10 V)
    WDRFA06-ACB1 - S-20-24-P1_ 20 l/min ACB1-R only With CAN J1939 (on request) Amplifier
    WDRFA06-ACB1 - S-20-24-P1R1 20 l/min ACB1-R only With CAN J1939 (on request) Controller with current feedback value signal (0…20 mA / 4…20 mA)
    WDRFA06-ACB1 - S-20-24-P1R2 20 l/min ACB1-R only With CAN J1939 (on request) Controller with voltage feedback value signal (0…10 V)
bottom of page